In addition to our tried and tested IUPS-401 for 230 VAC mains we now offer a new 110 VAC variant under the designation IUPS-401-110-B7. In general, power failures and strong voltage fluctuations in the mains supply can quickly become a big problem for IPC and embedded systems, causing costly failures, downtime or even data loss – but this does not have to happen!
With our integrated UPS (uninterruptible power supply) you get a reliable and comfortable solution for 5.25" installation. In the case of undervoltage / overvoltage or complete power failure, the IUPS takes over the supply of the connected system. If necessary, a controlled shutdown of the computer can be performed. The computer system and the UPS form a space-saving and compact unit.
Bicker IUPS-401-110-B7
All benefits at a glance
✓ Integrated AC UPS for 110 VAC (50 / 60Hz)
✓ Uninterruptible power supply with 400 VA
✓ Backup time at 100 W / 166 VA load: approx. 5 minutes
✓ Communication Interface Serial (D-Sub)
✓ Load sensor and reboot function
✓ Overload and overtemperature protection
✓ Front-side operating and signaling elements
✓ UPS management software included
✓ Quick and simple 5.25" installation
✓ Replaceable front panel white / black
✓ Excellent service & support
✓ Long-term availability at least 5 years

/// Reboot Function
If mains voltage returns after a power failure while Windows® is already shutting down, the UPS switches the PC off (after the shut-down period) and switches it on again after approximately 5 seconds in conjunction with RUPS 2000 and an ACPI-PC.
/// UPS Management Software
RUPS 2000 OEM UPS management software is included in delivery and supports operating systems Windows® 7 / 8 / 10 / 2008 Server / 2010 Server / 2012 Server.
RUPS 2000 OEM
The UPS management software is used to communicate between UPS and PC system. The intuitive user interface enables the monitoring and visualization of the power supply as well as the individual setting of all important parameters for normal or UPS operation. The shutdown function can be set individually, so that the PC is shut down in a defined manner and then the UPS is switched off.
|
 |
/// Load Sensor
The internal load sensor automatically checks whether a load (computer) is connected to the output. The IUPS-401-110-B7 will automatically shut down within approximately 20 seconds if no load is connected and no input voltage is detected. When the correct mains voltage returns, the IUPS automatically switches on and supplies the downstream load with 110 VAC mains voltage.
If you have any questions regarding the product and corresponding system integration, please do not hesitate to contact us! |